Home › Florida › Restaurant exhaust and hood cleaning schedule, Florida
Restaurant exhaust and hood cleaning schedule, Florida
- Pick what you need and give your kitchen's ZIP code.
- Each service goes to the number of local companies you choose, from one to five. We check licenses where the law requires one and email you their names.
- You talk with them and decide. You hire and pay the company directly.
Facts checked 2026-11-15.

NFPA 96 governs hood cleaning in Florida, because the state fire code adopts it. The standard ties inspection frequency to the amount of cooking, and grease found during an inspection means a cleaning by someone the fire marshal accepts. Commercial Kitchen 101 passes cleaning requests to local companies and does not clean anything.
The state's wording
Through the Florida Fire Prevention Code, 8th Edition, Florida adopts the 2021 edition of NFPA 96. The state amendment says contaminated parts of an exhaust system "shall be cleaned by a properly trained qualified, and certified person(s) acceptable to the AHJ". AHJ stands for authority having jurisdiction, and in most restaurants that means the local fire marshal.
A separate state license for hood cleaning did not turn up. The State Fire Marshal's dealer rules in Chapter 69A-21 deal with extinguishers and pre-engineered suppression systems, not with hoods. Acceptance is the fire marshal's call, and some fire districts post a list. One Florida district names several national and trade-school credentials and treats an uncertified vendor as a compliance problem. Another district could accept different credentials, so the question goes to your own office before anyone is hired.
Inspection schedule
NFPA 96 sets how often the exhaust system is inspected for grease. The table below is the schedule as the California Mechanical Code reprints it. Florida's edition may differ in places, and the fire marshal can confirm the details.
| Type of cooking | Inspect for grease buildup |
|---|---|
| Solid fuel cooking (wood or charcoal) | Monthly |
| High-volume cooking: 24-hour cooking, charbroiling, wok cooking | Quarterly |
| Moderate-volume cooking | Twice a year |
| Low-volume cooking: churches, day camps, seasonal businesses, senior centers | Yearly |
Buildup at an inspection triggers a cleaning. Which row describes your kitchen is the fire marshal's decision.
A local company can take it from here. One form, free for restaurants.
Get connectedScope of a thorough cleaning
NFPA 96 looks at the exhaust system as one assembly: hood, filters, ducts, fan and the parts that collect grease. A thorough cleaning:
- Reaches the hood, the plenum, the duct up to the roof and the fan, hard-to-reach sections included.
- Removes the filters and cleans or replaces them.
- Keeps the suppression system working, with cleaning chemicals kept off fusible links and detectors.
- Avoids flammable solvents.
- Leaves surfaces without powder or coating.
- Restores panels and dampers to their original positions.
- Switches off or locks out the equipment's controls before work begins.
A state health department guide to the 2011 NFPA 96 edition is the source of this list. Florida uses the 2021 edition, so the wording could differ, but the list works as a checklist when judging a cleaner.
The Florida Building Code requires cleanouts and access doors in the grease duct and hinged roof fans, so a cleaner can get in. Keep access panels uncovered. The hoods and exhaust guide has the construction side.
Label, certificate and report
Afterward you should have:
- A service label by the access panels, showing the company's name and the date.
- A certificate with the company, the individual who did the job and the date.
- A written report naming any areas left uncleaned or out of reach.
File them where the fire marshal can see them. A section the report calls unreachable still holds grease, so the access gets fixed and the section cleaned.
Before choosing a cleaner
- Find out from the fire marshal's office which cleaners and credentials are accepted.
- Request certificate numbers and a sample report from the company.
- Confirm whether the roof fan and the full duct are included, and what stays undone.
- If the same company handles suppression, Florida requires a State Fire Marshal license for that part, covered in the fire suppression guide.
Crews that work on duct systems might also need a chapter 489 contractor license if the job involves taking the system apart. Whether that reaches kitchen exhaust could not be confirmed, so the building department or fire marshal is the office to ask.
A cleaning request sent with your ZIP code and a target date goes to the number of local companies you choose (one to five).
Questions
What cleaning frequency does Florida use for restaurant hoods and ducts?
NFPA 96 calls for inspection monthly for solid fuel, quarterly for high-volume cooking, twice a year for moderate volume and yearly for low volume. Grease found must be cleaned, and the fire marshal picks the schedule.
Is there a state license for cleaning hoods in Florida?
None was found. Each fire marshal decides which cleaners are accepted, so that office is the one to ask first.
Which documents should a hood cleaner leave behind?
A service label near the access panels, plus a certificate naming the company, the person and the date. The written report should note any areas that were not cleaned.
Which office enforces the hood cleaning rules?
The local fire marshal acts as the authority having jurisdiction. That office enforces the Florida Fire Prevention Code, hood cleaning provisions included.
Sources
- NFPA 1 Florida amendments, 8th Edition Florida Fire Prevention Code (State Fire Marshal PDF)
- Rule 69A-3.012, adopted NFPA editions
- NFPA 96 inspection schedule as reprinted in California Mechanical Code 514.3
- West Manatee Fire Rescue, hood system maintenance letter
- Chapter 69A-21, Florida Administrative Code (State Fire Marshal PDF)
- Minnesota Department of Health, protection of kitchen cooking equipment