Commercial Kitchen 101 Get connected

Home › Florida › Kitchen hood, duct and makeup air code, Florida

Kitchen hood, duct and makeup air code, Florida

  1. Pick what you need and give your kitchen's ZIP code.
  2. Each service goes to the number of local companies you choose, from one to five. We check licenses where the law requires one and email you their names.
  3. You talk with them and decide. You hire and pay the company directly.
Get connected

Facts checked 2026-11-15.

A new stainless kitchen hood with baffle filters over a cooking line
A new hood over a cooking line.

In the Florida Building Code, a kitchen hood is one piece of a larger system made up of the hood, grease duct, exhaust fan and makeup air. All four are tested together before final approval. The building department and the fire marshal decide what they accept for a given building, and Commercial Kitchen 101 only passes requests on to local companies.

Two hood types

The Mechanical volume of the code sorts hoods into Type I and Type II.

The code carves out two exceptions to the Type I requirement: electric appliances that pass the UL 710B low-grease test, and listed solid-fuel pizza ovens vented directly.

A Type I hood bears a label with its minimum exhaust rate, in cubic feet per minute for each linear foot. Construction is steel of at least No. 18 gage or stainless of at least No. 20, with outside seams welded liquid-tight. Grease filters are listed to UL 1046.

Roof Ceiling Exhaust fan on the roofPulls smoke and grease up and out Grease ductWelded, sealed, with cleanout doors HoodBaffle filters catch grease Grease cup at the end FryerGriddleRange Cooking line: heat, smoke and grease rise into the hood Makeup airFresh air comes back into replace what leaves Room air
How a hood system moves air: up through the filters and duct, out the roof fan, with makeup air coming back in.

Airflow by cooking duty

The required rate rises with the heaviness of the cooking and depends on whether the hood hangs on a wall or over an island. Figures are cfm per linear foot of hood:

Cooking dutyWall-mounted canopySingle island canopy
Extra-heavy550700
Heavy400600
Medium300500
Light200400

Where a single hood covers different appliances, the heaviest one sets the rate. The code assigns appliances to duty classes, and a mechanical engineer or hood supplier can say where each one lands.

A local company can take it from here. One form, free for restaurants.

Get connected

The grease duct

This duct moves grease-laden air from the hood up to the roof. A fire inside it travels fast, which explains how strict the code is.

Cleaners get into the duct through those cleanouts. The hood cleaning guide covers inspection frequency and what follows a finding of grease.

Roof fans

A grease system uses "upblast" fans on the roof. The code wants them hinged and held by a flexible, weatherproof cable, with the duct rising at least 18 inches above the roof beneath the fan.

Makeup air and balance

What leaves through the hood has to be replaced. The code wants makeup air from every source to roughly equal the exhaust, and mechanical makeup air must start and run with the exhaust fan. Makeup air should differ from room temperature by no more than 10 degrees Fahrenheit, subject to an exception in the code. The design plans include an outdoor air balance schedule or diagram, and the installer can supply the schedule that matches them.

Suppression tied to the hood

An approved automatic suppression system is required for every appliance that needs a Type I hood. When the system discharges, it also cuts fuel or electric power to the cooking equipment. The fire suppression guide covers that system.

The performance test

Final approval calls for a performance test of the hood system. It measures exhaust airflow and makeup airflow and checks the design intent. Smoke or steam is used to confirm capture and containment.

A kitchen with a history

An older hood approval says little about its present state. A new tenant can ask for:

Adding a fryer or relocating a line of equipment often means changes to the hood and suppression system as well. A pre-engineered suppression system is installed within the limits it was tested for, so the licensed company confirms the layout before anything moves. The building department says whether the change needs a fresh permit.

Licenses for this work

Chapter 489 licenses mechanical and sheet metal contractors in Florida. The building department can say which contractor license it accepts for a hood and grease duct, since that varies. Suppression work is separate and needs a State Fire Marshal license. Doing or advertising contracting without the proper license is a crime, and the DBPR license search shows any contractor's status.

A request for hood, duct or exhaust fan work goes through the form to the number of local companies you choose (one to five).

Questions

Is a Type I hood needed in every commercial kitchen?

Only over cooking that produces grease or smoke. Dishwashers and other heat or moisture equipment take a Type II hood, and the code lists a few exceptions such as low-grease electric appliances passing UL 710B.

What height does the fan discharge need above a roof?

The grease duct discharge sits at least 40 inches above the roof surface. The duct under an upblast fan rises at least 18 inches, and the building department confirms what it enforces.

Who checks a hood system before a restaurant opens?

The Mechanical Code calls for a performance test ahead of final approval, covering exhaust, makeup air and smoke capture. The building department can say who it accepts to run that test.

How can I look up a hood contractor's license?

The DBPR license search at myfloridalicense.com lists contractors. Suppression companies hold a separate State Fire Marshal license.

Sources

  1. Florida Building Code, Mechanical 2023, chapter 5 (UpCodes copy)
  2. Florida Building Commission
  3. Florida Building Code, Building, chapter 9 (UpCodes copy)
  4. Florida Statutes 489.105, contractor definitions
  5. Florida Statutes 489.127, unlicensed contracting
  6. DBPR license search