Home › Texas › Dallas restaurant fire, grease and health rules
Dallas restaurant fire, grease and health rules
- Pick what you need and give your kitchen's ZIP code.
- Each service goes to the number of local companies you choose, from one to five. We check licenses where the law requires one and email you their names.
- You talk with them and decide. You hire and pay the company directly.
U.S. Bureau of Labor Statistics, private restaurants and other eating places
Facts checked 2026-11-15.

Restaurants and other eating places with employees numbered 5,533 in Dallas County in 2025, a rise of 5.3% from 5,253 in 2019. Many cities sit inside the county and each adopts its own codes, so this page sticks to the City of Dallas.
Dallas Fire-Rescue enforces a 2021 fire code with Dallas amendments
Inside Dallas Fire-Rescue, the Fire Prevention and Investigation Bureau contains the Inspection and Life Safety Education Division, which handles code enforcement, inspections and public education. A city memo from January 2023 lists the division's phone as 214-670-4319.
Chapter 16 of the Dallas City Code is the fire code. It is the 2021 International Fire Code with Dallas amendments, in effect since February 10, 2023. According to the city's memo, the amendments follow regional changes made through the North Central Texas Council of Governments, a base several North Texas cities draw on. A kitchen across the city line may be under a different edition.
The fee schedule lists a permit for kitchen fire-extinguishing systems
The schedule of permit fees that Dallas Fire-Rescue publishes includes a "Commercial Cooking Fire-Extinguishing System" permit at $250. It ties back to ordinance 32556, effective October 1, 2023, so the current amount is worth confirming with the city.
State licensing still determines who works on the system: a technician with a State Fire Marshal's Office license, employed by a registered company. The fire suppression guide explains that side.
A local company can take it from here. One form, free for restaurants.
Get connectedThe 2021 building, plumbing and mechanical codes took effect May 12, 2023
Dallas adopted the 2021 International Building Code (chapter 53), Plumbing Code (chapter 54) and Mechanical Code (chapter 55), each carrying Dallas amendments, and all three began on May 12, 2023. In the fire code text, a sprinkler system that protects a commercial kitchen exhaust hood goes inside the hood and duct system. The hoods and exhaust guide has the rest.
The city has its own Consumer Health Division
Dallas does its own restaurant health work through the Consumer Health Division in Code Compliance, which says it covers more than 7,000 permitted food establishments. The division does routine inspections by risk class, follow-up visits, complaint inspections and temporary event inspections. Grease trap overflows fall under its emergency response. Residents report problems by calling 311.
Two city offices handle grease
Grease belongs to the Pretreatment and Laboratory Services Division of Dallas Water Utilities, at 1020 Sargent Road, phone 214-670-6749. Its authority comes from the liquid waste ordinance in Dallas City Code chapter 19, article X.
- A grease trap, sized under the Dallas plumbing code, is required at every commercial or institutional food service operation.
- On the city's food service poster, the instruction is to empty the whole trap at the earlier of 90 days or the point when floating material, sediment, oil or grease takes up 25% of wetted height.
- Haulers must hold a City of Dallas permit and hand over a city trip ticket for you to sign before taking waste away.
- The final manifest stays at the restaurant for three years, according to the poster.
- A hauler's TCEQ registration comes first, and then each truck gets a city permit.
Separately, the Building Inspection department asks for a grease interceptor submittal alongside the construction documents of any site needing a health permit. It covers sizing under the plumbing code plus the maker's cut sheet. The guideline sheet still refers to the 2015 plumbing code, so ask which edition is in force.
Neither the poster nor the FAQ pages carry a date, and the city has revised its codes since they were written. Treat them as a starting point and verify with Dallas Water Utilities. The grease trap guide goes further.
Entering a Dallas County ZIP code and naming the kitchen job on the form sends the request to the number of local companies you choose (one to five), licensed where the work requires it.
Other places in Texas
Questions
Which Dallas office inspects restaurant kitchens for fire safety?
The Inspection and Life Safety Education Division of Dallas Fire-Rescue does, as part of the Fire Prevention and Investigation Bureau.
Is there a fire permit fee for a suppression system in Dallas?
Dallas Fire-Rescue's fee schedule shows a Commercial Cooking Fire-Extinguishing System permit at $250. The schedule rests on a 2023 ordinance, so check the amount before you budget.
What is the grease trap pumping rule for a Dallas restaurant?
The city poster calls for pumping every 90 days, or earlier when grease and solids fill 25% of the wetted height.
Sources
- Dallas Fire-Rescue, Prevention and Investigation Bureau
- Dallas city council memo, adoption of the International Fire Code (Jan 2023)
- Dallas current city codes
- Dallas 2021 International Fire Code amendments, ordinance 23-0118
- Dallas Fire-Rescue schedule of permit fees
- Dallas Consumer Health Division
- Dallas Liquid Waste program
- Dallas Pretreatment FAQ
- Dallas grease trap and interceptor poster
- Dallas grease interceptor submittal guidelines
- BLS QCEW, NAICS 7225, 2025
- BLS QCEW, NAICS 7225, 2019