Commercial Kitchen 101 Get connected

Home › Equipment › Commercial dishwashers

Commercial dishwashers: types, racks, hot or chemical

  1. Pick what you need and give your kitchen's ZIP code.
  2. Each service goes to the number of local companies you choose, from one to five. We check licenses where the law requires one and email you their names.
  3. You talk with them and decide. You hire and pay the company directly.
Get connected

Facts checked 2026-11-15.

A commercial dishwasher washes and sanitizes dishes, glasses and pots, using hot water or a chemical. Volume decides the type, from an undercounter machine to a conveyor. The next choice, hot or chemical sanitizing, decides what the kitchen has to supply.

Machine types and capacity

ENERGY STAR lists undercounter, single-tank door-type, pot, pan and utensil, and glasswashing stationary rack machines, plus rack and flight-type conveyors, in high and low temperature. Hobart's LXnR undercounter is high temperature, rated at 30, 24 and 13 racks an hour on light, normal and heavy soil, and 0.62 gallons a cycle. Jackson's Conserver XL2 is a chemical-sanitizing door-type rated at 82 racks an hour and 1.06 gallons a rack. CMA's EST 44 conveyor is rated at 249 racks an hour. Champion's catalog spans glass washers, door-type machines, rack and flight conveyors and pot and pan washers.

Hobart, Jackson, CMA and Champion each publish their own ratings.

What each state requires

Florida: DBPR's Division of Hotels and Restaurants applies the 2017 Food Code through Rule 61C-4.010. The plan packet looks for a three-compartment sink or a commercial dishwasher, and a sanitizer indicator on newer dish machines.

Texas: 25 TAC 228 and the 2017 Food Code apply, and the plan lists the machine with its maker, model, location and capacity.

Georgia: DPH Chapter 511-6-1 uses the 2022 Food Code, and Georgia Power lists a commercial rebate on ENERGY STAR dishwashers, excluding low-temperature machines. Check the program's rules before you count on it.

The Food Code is specific about dish machines. The machine needs a data plate showing wash, rinse and sanitize temperatures, rinse pressure, and conveyor speed or cycle time, and it must be run to the data plate and the maker's instructions. Hot-water machines have minimum wash and rinse temperatures that depend on the machine type, and a sanitizing rinse of 165 or 180 degrees Fahrenheit, with a 194 degree ceiling, under the 2022 edition. Chemical machines have their own temperature, concentration and EPA label rules. Rinse pressure runs between 5 and 30 psi. Ask the local health department which edition's numbers it uses. NSF/ANSI 3 covers warewashing equipment.

UL's guide says some commercial dishwashing appliances must sit under a Type II hood for heat and steam, and does not name which. Ask the building department, and read the hood guides for Florida, Texas and Georgia.

Get prices for this item. One request, and you pick how many sellers quote it.

Get quotes

Efficiency

ENERGY STAR rates idle energy, by machine type and temperature, and water used in the final rinse. Pre-rinse spray valves, the hand sprayer at the dish station, have a federal limit in 10 CFR 431.266: for valves made on or after January 28, 2019, flow tops out at 1.00, 1.20 or 1.28 gallons per minute, depending on spray force. Use the ENERGY STAR Rebate Finder with your ZIP code, and ask your utility.

What to ask a seller

  1. Pick high temperature or chemical, and ask what each needs from the building: a booster heater, a 180 degree rinse, or a sanitizer supply.
  2. Compare racks per hour and water per rack against your volume.
  3. Get the electrical, water inlet temperature and pressure needs.
  4. Look for the NSF/ANSI 3 mark and ENERGY STAR.
  5. Ask whether the model needs a Type II hood or a condensate hood where you are.
  6. Read the warranty. Jackson lists one year on parts and labor for the XL2.

Send one request for a dishwasher and it is passed to as many local sellers as you pick, up to five.

Other kitchen equipment

Questions

What is the difference between high-temperature and chemical dishwashers?

A high-temperature dishwasher sanitizes with hot water, often a 180 degree rinse, while a chemical machine uses a sanitizer. High-temperature units usually need a booster heater.

Does a commercial dishwasher need a hood?

A commercial dishwasher needs a Type II hood in some cases, according to UL's guide. The guide does not name which machines, so ask the building department in your city.

How many racks per hour does a commercial dishwasher wash?

A commercial dishwasher washes from about 13 racks an hour on heavy soil in an undercounter to 249 on a conveyor, using the Hobart and CMA ratings. Pick by your peak hour.

Is there an ENERGY STAR commercial dishwasher?

An ENERGY STAR commercial dishwasher exists for undercounter, door-type, pot and pan, and conveyor machines. The label rates idle energy and final rinse water.

Sources

  1. FDA 2022 Food Code
  2. NSF certified listings, standard 3
  3. UL, Commercial Cooking Marking and Application Guide
  4. ENERGY STAR, commercial dishwashers
  5. 10 CFR 431.266, pre-rinse spray valves
  6. Georgia Power commercial rebates
  7. ENERGY STAR Rebate Finder
  8. Hobart LXnR undercounter
  9. CMA dish machines
  10. Champion products
  11. FDA 2017 Food Code
  12. Rule 61C-4.010, Florida Administrative Code
  13. DBPR plan review packet (HR-7030)
  14. DSHS retail food establishments
  15. 25 TAC 228.241, plans
  16. Georgia DPH food service
  17. Georgia Rule 511-6-1-.02, plans
  18. Georgia Rule 511-6-1-.05, equipment